HomeSearch by PurposeAssociating with Other Systems or Applications

Associating with Other Systems or Applications

To configure SNMP settings for obtaining or monitoring information of this machine through a computer ([SNMP Setting])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [SNMP Setting]

Configure the settings to obtain information of this machine or to monitor the machine using Simple Network Management Protocol (SNMP).

Setting

Description

[SNMP Setting]

When enabling SNMP, set this option to ON (default: ON).

  • [SNMP v1/v2c(IP)]: When using SNMP v1 or SNMP v2, set this option to ON (default: ON).

  • [SNMP v3(IP)]: When using SNMP v3, set this option to ON (default: ON).

[UDP Port Setting]

If necessary, change the UDP port number (default: [161]).

[SNMP v1/v2c Setting]

Configure SNMP v1/v2c settings.

  • [Read Community Name]: Enter a read-only community name (using 1 to 15 characters, excluding spaces, \, ', ", and #) (default: [public]).

  • [Write Community Name]: When allowing reading and writing, set this option to ON (default: ON). Also enter a community name used for reading and writing (using 1 to 15 characters, excluding spaces, \, ', ", and #) (default: [private]).

[SNMP v3 Setting]

Configure SNMP v3 settings.

  • [Context Name]: Enter the context name (using up to 63 characters, excluding spaces, \, ', ", and #).

  • [Discovery User Name]: When allowing the detection user, set this option to ON (default: ON). Also, enter a user name for detection (using 1 to 32 characters, excluding spaces, \, ', ", and #) (default: [public]).

  • [Read User Name]: Enter a read-only user name (using up to 32 characters, excluding spaces, \, ', ", and #) (default: [initial]).
    [Security Level]: Select a security level of the user in the read-write enable state (default: [auth-password/priv-password]).
    [auth-password]: If [auth-password] or [auth-password/priv-password] is selected from [Security Level], enter an authentication password for the read-only user (using 8 to 32 characters, excluding spaces, \, ', ", and #).
    [priv-password]: If [auth-password/priv-password] is selected from [Security Level], enter a password used for privacy (encryption) of the read-only user (using 8 to 32 characters, excluding spaces, \, ', ", and #).

  • [Write User Name]: Enter the user name of the user in the read-write enable state (using up to 32 characters) (default: [restrict]).
    [Security Level]: Select a security level of the user in the read-write enable state (default: [auth-password/priv-password]).
    [auth-password]: If [auth-password] or [auth-password/priv-password] is selected from [Security Level], enter an authentication password for the read-write enabled user (using 8 to 32 characters, excluding spaces, \, ', ", and #).
    [priv-password]: If [auth-password/priv-password] is selected from [Security Level], enter a password used for privacy (encryption) of the read-write enabled user (using 8 to 32 characters, excluding spaces, \, ', ", and #).

  • [Encryption Algorithm]: Select an encryption algorithm (default: [DES]).

  • [Authentication Method]: Select an authentication algorithm (default: [MD5]).

[TRAP Setting]

Configure settings for the SNMP TRAP function.

  • [Allow Setting]: Select whether to allow a notification of the status of this machine using the SNMP TRAP function (default: [Allow]).

  • [Trap Setting when Authentication Fails]: Select whether to send TRAP when authentication fails (default: [OFF]).

To configure SSDP settings for searching a service on the network ([SSDP Settings])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [SSDP Settings]

Enabling SSDP (Simple Service Discovery Protocol) allows that software on the network or other services search for services which can be supplied by this machine. It also notifies that services have been started on this machine.

This function is available when using services such as OpenAPI.

Setting

Description

[SSDP]

When enabling SSDP, set this option to ON (default: ON).

[Multicast TTL Setting]

Change TTL (Time To Live) for SSDP multi-cast packet if necessary (default: [1]).

To configure SNMP settings for automatically detecting this machine using the TWAIN driver ([SNMP Setting])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [SNMP Setting]

Configure the settings to obtain information of this machine or to monitor the machine using Simple Network Management Protocol (SNMP).

Setting

Description

[SNMP Setting]

When enabling SNMP, set this option to ON (default: ON).

  • [SNMP v1/v2c(IP)]: When using SNMP v1 or SNMP v2, set this option to ON (default: ON).

  • [SNMP v3(IP)]: When using SNMP v3, set this option to ON (default: ON).

[UDP Port Setting]

If necessary, change the UDP port number (default: [161]).

[SNMP v1/v2c Setting]

Configure SNMP v1/v2c settings.

  • [Read Community Name]: Enter a read-only community name (using 1 to 15 characters, excluding spaces, \, ', ", and #) (default: [public]).

  • [Write Community Name]: When allowing reading and writing, set this option to ON (default: ON). Also enter a community name used for reading and writing (using 1 to 15 characters, excluding spaces, \, ', ", and #) (default: [private]).

[SNMP v3 Setting]

Configure SNMP v3 settings.

  • [Context Name]: Enter the context name (using up to 63 characters, excluding spaces, \, ', ", and #).

  • [Discovery User Name]: When allowing the detection user, set this option to ON (default: ON). Also, enter a user name for detection (using 1 to 32 characters, excluding spaces, \, ', ", and #) (default: [public]).

  • [Read User Name]: Enter a read-only user name (using up to 32 characters, excluding spaces, \, ', ", and #) (default: [initial]).
    [Security Level]: Select a security level of the user in the read-write enable state (default: [auth-password/priv-password]).
    [auth-password]: If [auth-password] or [auth-password/priv-password] is selected from [Security Level], enter an authentication password for the read-only user (using 8 to 32 characters, excluding spaces, \, ', ", and #).
    [priv-password]: If [auth-password/priv-password] is selected from [Security Level], enter a password used for privacy (encryption) of the read-only user (using 8 to 32 characters, excluding spaces, \, ', ", and #).

  • [Write User Name]: Enter the user name of the user in the read-write enable state (using up to 32 characters) (default: [restrict]).
    [Security Level]: Select a security level of the user in the read-write enable state (default: [auth-password/priv-password]).
    [auth-password]: If [auth-password] or [auth-password/priv-password] is selected from [Security Level], enter an authentication password for the read-write enabled user (using 8 to 32 characters, excluding spaces, \, ', ", and #).
    [priv-password]: If [auth-password/priv-password] is selected from [Security Level], enter a password used for privacy (encryption) of the read-write enabled user (using 8 to 32 characters, excluding spaces, \, ', ", and #).

  • [Encryption Algorithm]: Select an encryption algorithm (default: [DES]).

  • [Authentication Method]: Select an authentication algorithm (default: [MD5]).

[TRAP Setting]

Configure settings for the SNMP TRAP function.

  • [Allow Setting]: Select whether to allow a notification of the status of this machine using the SNMP TRAP function (default: [Allow]).

  • [Trap Setting when Authentication Fails]: Select whether to send TRAP when authentication fails (default: [OFF]).

To configure the TCP Socket operating environment ([TCP Socket Setting])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [TCP Socket Setting]

Configure settings to establish a communication via TCP Socket.

Setting

Description

[TCP Socket]

When using TCP Socket, set this option to ON (default: ON).

  • [Port No.]: If necessary, change the TCP Socket port number (default: [59158]).

[Use SSL/TLS]

When using SSL communications, set this option to ON (default: OFF).

  • [Port No.(SSL/TLS)]: If necessary, change the port number for SSL communication (default: [59159]).

To notify the Mopria-compatible Android terminal of Mopria support information for this machine when searching for this machine ([Mopria Setting])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [Mopria Setting]

Configure settings to use Mopria on this machine.

Setting

Description

[Print Setting]

Here

To configure settings for associating with a mobile terminal ([Simple Connection Setting])

To display:
  • [Utility]
    • [Administrator]
      • [System Settings]
        • [System Connection Setting]
          • [Mobile Connection Settings]

Configure a setting to connect this machine to a mobile terminal.

Setting

Description

[Simple Connection Setting]

Configure functions to associate with a mobile terminal.

  • [QR Code Display Setting]: When displaying wireless connection information of this machine using the QR code, set this option to ON (default: OFF).

  • [Enable NFC]: When using NFC, set this option to ON (default: OFF).

  • [Enable Bluetooth LE]: When using the Bluetooth LE, set this option to ON (default: OFF).

[Wireless Connection Setting]

Specify information required to connect from a mobile terminal to this machine in wireless mode. This option is available when [QR Code Display Setting] or [Enable NFC] is used in [Simple Connection Setting].

  • [Wireless Connection Setting]: When connecting from a mobile terminal to this machine in wireless mode, set this option to ON (default: OFF).

  • [Wireless Connection Method]: Specify the method to establish a wireless connection between a mobile terminal and this machine (default: [Use MFP Wireless Setting]). If [Individual Settings] is selected, configure the following settings.
    [SSID]: Enter the SSID of the access point (using up to 32 characters).
    [Authentication/Encryption Algorithm]: Select the algorithm used for authentication or encryption (default: [No Authentication/Encryption]).
    Specify [Key Input Method] and [WEP Key] when [WEP] is selected in [Authentication/Encryption Algorithm].
    When an algorithm other than [WEP] or [No Authentication/Encryption] is selected in [Authentication/Encryption Algorithm], specify [Key Input Method] and [Passphrase].

When [Network I/F Configuration] is set to [Wireless Only], a pairing is established by applying the wireless settings of this machine; therefore, this setting is not displayed.

[Touch Connection Link Application Settings]

When you place the Android terminal on the Mobile Touch Area of this machine, select an application to be started preferentially (default: [Konica Minolta Mobile Print]).

To configure settings for establishing a wireless connection with a mobile terminal ([Wireless Connection Setting])

To display:
  • [Utility]
    • [Administrator]
      • [System Settings]
        • [System Connection Setting]
          • [Mobile Connection Settings]

Configure a setting to connect this machine to a mobile terminal.

Setting

Description

[Simple Connection Setting]

Configure functions to associate with a mobile terminal.

  • [QR Code Display Setting]: When displaying wireless connection information of this machine using the QR code, set this option to ON (default: OFF).

  • [Enable NFC]: When using NFC, set this option to ON (default: OFF).

  • [Enable Bluetooth LE]: When using the Bluetooth LE, set this option to ON (default: OFF).

[Wireless Connection Setting]

Specify information required to connect from a mobile terminal to this machine in wireless mode. This option is available when [QR Code Display Setting] or [Enable NFC] is used in [Simple Connection Setting].

  • [Wireless Connection Setting]: When connecting from a mobile terminal to this machine in wireless mode, set this option to ON (default: OFF).

  • [Wireless Connection Method]: Specify the method to establish a wireless connection between a mobile terminal and this machine (default: [Use MFP Wireless Setting]). If [Individual Settings] is selected, configure the following settings.
    [SSID]: Enter the SSID of the access point (using up to 32 characters).
    [Authentication/Encryption Algorithm]: Select the algorithm used for authentication or encryption (default: [No Authentication/Encryption]).
    Specify [Key Input Method] and [WEP Key] when [WEP] is selected in [Authentication/Encryption Algorithm].
    When an algorithm other than [WEP] or [No Authentication/Encryption] is selected in [Authentication/Encryption Algorithm], specify [Key Input Method] and [Passphrase].

When [Network I/F Configuration] is set to [Wireless Only], a pairing is established by applying the wireless settings of this machine; therefore, this setting is not displayed.

[Touch Connection Link Application Settings]

When you place the Android terminal on the Mobile Touch Area of this machine, select an application to be started preferentially (default: [Konica Minolta Mobile Print]).

To specify the application to be started preferentially when you place the mobile terminal on the mobile touch area ([Touch Connection Link Application Settings])

To display:
  • [Utility]
    • [Administrator]
      • [System Settings]
        • [System Connection Setting]
          • [Mobile Connection Settings]

Configure a setting to connect this machine to a mobile terminal.

Setting

Description

[Simple Connection Setting]

Configure functions to associate with a mobile terminal.

  • [QR Code Display Setting]: When displaying wireless connection information of this machine using the QR code, set this option to ON (default: OFF).

  • [Enable NFC]: When using NFC, set this option to ON (default: OFF).

  • [Enable Bluetooth LE]: When using the Bluetooth LE, set this option to ON (default: OFF).

[Wireless Connection Setting]

Specify information required to connect from a mobile terminal to this machine in wireless mode. This option is available when [QR Code Display Setting] or [Enable NFC] is used in [Simple Connection Setting].

  • [Wireless Connection Setting]: When connecting from a mobile terminal to this machine in wireless mode, set this option to ON (default: OFF).

  • [Wireless Connection Method]: Specify the method to establish a wireless connection between a mobile terminal and this machine (default: [Use MFP Wireless Setting]). If [Individual Settings] is selected, configure the following settings.
    [SSID]: Enter the SSID of the access point (using up to 32 characters).
    [Authentication/Encryption Algorithm]: Select the algorithm used for authentication or encryption (default: [No Authentication/Encryption]).
    Specify [Key Input Method] and [WEP Key] when [WEP] is selected in [Authentication/Encryption Algorithm].
    When an algorithm other than [WEP] or [No Authentication/Encryption] is selected in [Authentication/Encryption Algorithm], specify [Key Input Method] and [Passphrase].

When [Network I/F Configuration] is set to [Wireless Only], a pairing is established by applying the wireless settings of this machine; therefore, this setting is not displayed.

[Touch Connection Link Application Settings]

When you place the Android terminal on the Mobile Touch Area of this machine, select an application to be started preferentially (default: [Konica Minolta Mobile Print]).

To configure the operating environment when operating this machine through a mobile terminal using bizhub Remote Access ([bizhub Remote Access Setting])

To display:
  • [Utility]
    • [Administrator]
      • [Network]
        • [bizhub Remote Access Setting]

Configure communication settings to connect a mobile terminal to this machine using bizhub Remote Access and transfer image data or operation contents of the screen of this machine.

Setting

Description

[bizhub Remote Access Setting]

When permitting a connection from a mobile terminal using bizhub Remote Access, set this option to ON (default: OFF).

[Connection Method]

Select whether to give priority to the operation speed in a mobile terminal or give priority to the image quality of the mobile terminal screen (default: [Standard]).

[Connection Timeout]

If necessary, change the time-out time to limit a communication with the mobile terminal (default: [20] min.).

[Operation Change Screen]

Specify the operation to be performed when the screen of this machine is operated during remote control using a mobile terminal. When displaying the confirmation screen to check whether to continue remote control on the screen of a mobile terminal, set this option to ON (default: ON).

[Connection Permission Screen]

Specify the operation to be performed when a remote control connection request is issued from a mobile terminal while the user is operating the screen of this machine. When displaying the confirmation screen to check whether to allow a connection to this machine, set this option to ON (default: ON).

[Priority start mode]

Select which mode is used to start bizhub Remote Access by placing the Android terminal on the Mobile Touch Area (default: [Panel Link]).

  • To use bizhub Remote Access, you need to install bizhub Remote Access on the mobile terminal. In addition, you need to enable [TCP Socket] in [TCP Socket Setting] (Here).

  • Configure NFC/Bluetooth LE settings on this machine to suit your environment. For details, refer to Here.

To display network information of this machine on the screen of this machine as a QR code ([Simple Connection Setting])

To display:
  • [Utility]
    • [Administrator]
      • [System Settings]
        • [System Connection Setting]
          • [Mobile Connection Settings]

Configure a setting to connect this machine to a mobile terminal.

Setting

Description

[Simple Connection Setting]

Configure functions to associate with a mobile terminal.

  • [QR Code Display Setting]: When displaying wireless connection information of this machine using the QR code, set this option to ON (default: OFF).

  • [Enable NFC]: When using NFC, set this option to ON (default: OFF).

  • [Enable Bluetooth LE]: When using the Bluetooth LE, set this option to ON (default: OFF).

[Wireless Connection Setting]

Specify information required to connect from a mobile terminal to this machine in wireless mode. This option is available when [QR Code Display Setting] or [Enable NFC] is used in [Simple Connection Setting].

  • [Wireless Connection Setting]: When connecting from a mobile terminal to this machine in wireless mode, set this option to ON (default: OFF).

  • [Wireless Connection Method]: Specify the method to establish a wireless connection between a mobile terminal and this machine (default: [Use MFP Wireless Setting]). If [Individual Settings] is selected, configure the following settings.
    [SSID]: Enter the SSID of the access point (using up to 32 characters).
    [Authentication/Encryption Algorithm]: Select the algorithm used for authentication or encryption (default: [No Authentication/Encryption]).
    Specify [Key Input Method] and [WEP Key] when [WEP] is selected in [Authentication/Encryption Algorithm].
    When an algorithm other than [WEP] or [No Authentication/Encryption] is selected in [Authentication/Encryption Algorithm], specify [Key Input Method] and [Passphrase].

When [Network I/F Configuration] is set to [Wireless Only], a pairing is established by applying the wireless settings of this machine; therefore, this setting is not displayed.

[Touch Connection Link Application Settings]

When you place the Android terminal on the Mobile Touch Area of this machine, select an application to be started preferentially (default: [Konica Minolta Mobile Print]).